+8617822459937

Main Technical Features ● Integrated filtration: It adopts one-piece box structure, and the inside can flexibly carry multi-stage filter materials such as primary (G4), intermediate (F8) and high efficiency (H13/H14) to form a complete system...
● Integrated filtration: It adopts one-piece box structure, and the inside can flexibly carry multi-stage filter materials such as primary (G4), intermediate (F8) and high efficiency (H13/H14) to form a complete filtration system. It can purify the air to its entire depth. Customized Air Volume: Equipped with a special fan, the air volume varies from 500m³/h to 50,000m³/h, which can be customized according to actual demand to meet the cleaning requirements of different rooms. Convenient Maintenance: The box is equipped with an access door, the filter is installed in a drawer, and the filter media can be quickly replaced by opening the access door, which simplifies operation and shortens the maintenance cycle. Clogging alarm function, timely reminder of the need for replacement. Strong adaptability: The box body material is available in polyurethane sandwich panel and stainless steel, etc. Polyurethane sandwich panel is suitable for general environment, and stainless steel can be used in humid and corrosive environment to extend the life of equipment.
● The main function of the fresh air filter is to “purify the introduced outdoor air”, so all places that need to improve the indoor air quality through the fresh air system (especially densely populated, cleanliness requirements or more severe outdoor air pollution). Therefore, all places where there is a need to improve indoor air quality with fresh air systems (especially densely populated areas that require cleanliness or places with high levels of outdoor air pollution) use them. For example, high-end apartments and villas, hotels, shopping malls, chess and card rooms and other commercial premises, hospital wards, pharmaceutical workshops, electronic and food factories and other industrial production, different places have different requirements for filtration precision (for example, hospitals, pharmaceutical factories need high-efficiency filtration, ordinary homes can be selected according to the pollution level in the local medium- and low-efficiency filtration), but the main requirement is to protect indoor air by filtration for to ensure health and safety or to meet specific production/preservation standards. The main requirement is to ensure indoor air health and safety or meet specific production/preservation standards through filtration.
● Primary section: panel filter made of G4 polyester non-woven fabric (washable metal mesh optional), intercepting particles ≥5 microns in size;
● Intermediate section: bag filter brand F7, filtering particles 0.5 microns in size;
● High efficiency section: H13 grade filter (ULPA optional), providing 0.3 micron particle filtration efficiency ≥99.97%; Functional section: H13 grade filter (ULPA optional), providing 0.3 micron particle filtration efficiency ≥99.97%; Function 99.97%; Functional section: optional activated carbon filter (iodine content ≥ 800 mg/g), photocatalytic filter or UV sterilization module (sterilization rate ≥ 99%). Fan system: low noise centrifugal fan. Housing construction: polyurethane sandwich panel or stainless steel.
● Multi-stage synergetic filtration: three-stage combination of filtration of 0.3-10 micron particles with a removal rate of ≥ 99.5% than one high-efficiency filter to extend the service life by 2 times (pre-filtration to intercept large particles);
● can be increased or decreased according to the needs of the functional section (for example, increasing the activated carbon or UV section). Functional sections can be added or removed as needed (such as adding an activated carbon section or a UV module) to meet a variety of cleaning needs, from dust to odors and microorganisms.
● Mobile models: placed on a horizontal platform after unpacking, connected to a power source, can be used, a space of ≥ 500 mm is reserved on the air inlet side;
● Models with duct connection: inlet and outlet and joining of duct flanges;
● Replacement cycle: primary section: from 1-2 months (clean environment) to 2-4 weeks (dusty environment); intermediate section: from 1-2 months (clean environment) to 2-4 weeks (dusty environment); intermediate section: 2-4 weeks (dusty environment). Replacement period: primary section: from 1-2 months (clean environment) to 2-4 weeks (dusty environment); intermediate section: 3-6 months (three-stage filtration); High efficiency section: 1-2 years, mandatory replacement when resistance reaches final resistance.
1. PACKAGING, DELIVERY
● Rigid box + pallet + moisture-proof film packaging
● Support for international logistics, sea / land transport.
2.Delivery, sample
● Shipping: Spot products will be shipped within 48 hours, custom products will be shipped within 7-10 days (depending on size and performance level), logistics tracking number will be provided.
● Samples: Free standard samples (customer bears shipping cost), 2-3 days.
3.after-sales settlement
● Payment: T/T / partial prepayment
● 3 months warranty (unconditional replacement of defective products)
4.qualification, certification
● ISO 9001 quality management system certification
● ISO14001 environmental management system certification
● ISO45001 occupational health and safety management system certification
● Third Party Audit Report (CNAS)